Overview
This Knowledge Base article explains how to configure the optical output of the Neumann MT 48 in Music Mission to receive a constant digital signal level to an external metering device (e.g. TC Electronic Clarity or simlar)
The objective is to ensure that the signal level received by the external meter remains independent of the monitoring volume set on the MT 48.
This configuration allows loudness measurements, peak-level monitoring, and other signal analyses to be performed independently of the listening volume.
To achieve this, Mix 2 is used as a dedicated metering bus that follows the signal of Mix 1 while maintaining an independent output volume.
Prerequisites
- Neumann MT 48 operating in Music Mission
- External metering device with an optical input
- Optical Toslink connection between the MT 48 and the metering device
Step-by-Step Configuration
1. Configure the Optical Output for S/PDIF or ADAT. Depending on which digital format your measuring device supports, you must set this option first.
- Open the MT 48 settings.
- Navigate to the optical interface configuration.
- Change the optical output mode depending your need from ADAT to S/PDIF.
- Verify that the external metering device receives a valid digital signal.
2. Enable “Mix 2 follows Mix 1”
- On the MT 48, navigate to MENU | SETTINGS | MONITORING.
- Enable Mix 2 follows Mix 1.
This allows Mix 2 to follow the channel mix of Mix 1 without having to share its output volume setting.
Consequently, changes to the individual channel levels in Mix 1 are also reflected in the signal supplied to the external meter.
3. Configure the S/PDIF Output in the Bus Routing Matrix
- Open the BUS ROUTING on MT 48 Remote Control software.
- Navigate to the Bus Routing Matrix.
- If applicable, remove the existing routing that mirrors the analog monitor output to the optical S/PDIF output.
- Configure the following routing assignments (Screenshot 2)
4. Set the Mix 2 Output Volume to 0 dB
- Open the mix selection menu in the MT 48 Remote Control software.
- Select MIX2 (MIX1).
- Set the output volume of Mix 2 to 0.0 dB.
- Switch back to Mix 1.
A setting of 0 dB corresponds to unity gain, meaning that no additional gain or attenuation is applied by the
Mix 2 output volume control.
The monitoring volume of Mix 1 can still be adjusted independently.
Important: Before increasing the Mix 2 output volume, ensure that Mix 2 is not inadvertently routed to a loudspeaker output. Otherwise, the loudspeakers could receive an unexpectedly high signal level.
Verification Procedure
After completing the configuration, verify that the signal routing and volume controls operate as intended.
- Play a continuous audio signal through Mix 1.
- Check the signal level displayed on the external metering device.
- Adjust the monitoring volume of Mix 1 using the MT 48 volume controller.
- Observe the signal level displayed on the external meter.
Additional Notes
This procedure applies specifically to the Music Mission of the Neumann MT 48. Different routing and monitoring settings may be required when operating in Monitor Mission.
Menu names and locations may vary depending on the installed firmware and Remote Control software version.
Setting Mix 2 to 0 dB ensures that its output volume control does not introduce additional attenuation or gain. However, the actual signal level still depends on the source signal and the channel levels within the mix.
For reliable loudness measurements, ensure that no additional processing or level adjustments are applied to the metering signal path.