If you want to listen to the same AES67/RAVENNA source on several outputs, you have to use the device Internal Router, as having several sinks connected to the same source is not possible.
- Connect your Source to one of the required outputs, with Aneman or the devices Advanced Pages.
The connection must be multicast. - Open the ZMAN-based device Advanced page, with Aneman, MTDiscovery, MAD or VAD Panel.
In this example, we will use Hapi MKII. - Go in the Sinks tab
- Select the Source in the Source drop down menu.
- Use the Router in the Channels section.
Notes:
On Anubis, if you route directly to a physical output (XLR 1/2 or Headphone for example), the Anubis rotary volume knob will not apply. If the volume knob is required, please route to an Anubis Source (DAW 1-2 for example).
The outputs are exclusive, it is not possible to route 2 (or more) sources on the same output; e.g. routing Stereo Source 1 and 2 on SPDIF is not possible.
Routing to Peered devices is possible from the Main device Session Sinks page.
Multicast connection is mandatory, Unicast is not possible.
Legacy devices: the internal Router is not available in legacy devices, such as Horus or Hapi MKI, it is not possible to listen to the same source on several outputs.