- Custom IO Naming in your RAVENNA/AES67 device
- Custom IO Naming in your Dante device
- Custom IO Naming in Pyramix / Ovation MassCore
Custom IO Naming in your RAVENNA/AES67 device
Prerequisites
MTDiscovery installed.
Web browser (Google Chrome recommended)
Merging / Neumann device(s) running firmware 2.1 (or above) in RAVENNA/AES67 mode.
Note: Legacy devices Horus or Hapi MKI not compatibleNetwork streams (sources - sinks) cannot be renamed.
Procedure
Start MTDiscovery
Right-Click on your connected Merging / Neumann RAVENNA/AES67 device and select Open Advanced Pages
Display the IO Router tab
Right click in the channel number part of the IO you want to rename, and click on Rename IO
IO Router tab with renamed IOs
Note for MAD/VAD users: use Unite mode to get the renamed IOs in your DAW.
Custom IO Naming in your Dante device
Prerequisites
Dante Controller installed
Merging / Neumann device(s) running in Dante mode.
Limitations
Only Dante channels can be renamed, and only visible in the Dante layer.
If a device or channel is renamed, Dante routing considers it to be a different device or channel.
Channel names must be unique on a device
Procedure
Start Dante Controller
Access the Device View page by double clicking on your device in the Routing, Device Info, Clock or Network status tab.
Channels can be renamed in the Transmit / Receive tabs
Renamed Dante Channels in Routing tab:
Custom IO Naming in Pyramix / Ovation MassCore
Prerequisites
Pyramix / Ovation MassCore installed and authorized.
MTDiscovery installed.
Web browser (Google Chrome recommended)
-
Merging / Neumann RAVENNA/AES67 device(s) connected to your MassCore network adapter
Procedure
Note: Don’t use ANEMAN under such configuration; it will overwrite your customized I/O naming convention
Start Pyramix / Ovation MassCore application.
Make sure MassCore and your connected Merging / Neumann RAVENNA/AES67 device are running at the same sampling rate.
Start MTDiscovery
Right-Click on your connected Merging / Neumann device and select Open Advanced Pages
Right-Click on your MassCore device and select Open Advanced Pages.
Note: the MassCore entry line is only available if Pyramix/Ovation is running.
Customize Inputs Naming
Personalize the Input naming on the device side
Go in the device Advanced page - Sources section.
Press the Create Source button
Enter your custom name.
Violins is the name of the input banks we would like to see in the MassCore mixer.Select the required IO in the Channels section.
In this example, we will use the ADA 1 module.
Note: do not edit any of the other entries.
Personalize the Input naming for a second A/D Module
Create a Source
Enter your custom name for the second AD module
Woodwinds is the name of the input bank we would like to see in the MassCore mixer.Select the required IO in the Channels section.
In this example, we will use the ADA 2 module.
Personalize the Input Naming on the MassCore side
In your browser, go in your MassCore device page, Sinks section.
Press the Create Sink button
Click in the Source field, and select your customized first module bank.
If you have created a second input source, repeat the same operation for the second module.
Note: do not edit any of the other entries.Within your Pyramix Mixer your should now see your customized modules appear under the inputs available.
Customize Outputs Naming
Personalize the Output Naming on the MassCore side
In your browser, go in your MassCore device page, Sources section.
Press the Create Source button
Enter your custom name.
Speakers 7.1 is the name of the input banks we would like to see in the MassCore mixer.
Note: do not edit any of the other entries
Personalize the Output naming on the device side
In your browser, go in the device Advanced page, and Sinks section.
Press the Create Sink button
Click in the Source field, and select your customized MassCore source, by clicking on the down arrow.
Select the required IO in the Channels section.
In this example, we will use the AES module.Within your Pyramix Mixer your should now see the customized naming convention appear under the Outputs available
Important notes
Do not use ANEMAN under such configuration as it will overwrite your customized I/O naming convention.
Long Names can end up truncated in the Mixer I/O entries
-
Backing up your customized configuration has to be done on two sides.
Device: Save your I/O configuration as a Preset.
MassCore: Back up the MassCore_RAVENNA.cfg file located under
C:\Users\<USER NAME>\AppData\Roaming\Merging Technologies
Note: if your customized configuration gets lost you can recall the device preset and replace the MassCore_RAVENNA.cfg
The Advanced RAVENNA routing entries can be removed and cleanup by opening the device and MassCore advanced pages.
Then manually delete the Tabs Sessions “sources” and “sinks” entries for both the device and MassCore browser pages.